From: Calculate excess mortality during heatwaves using Hilbert-Huang transform algorithm
Model | Coef. of maxT | Coef. of PM10 | Coef. of O3 | p-value | Adjusted R2 | Year (91Â days) |
---|---|---|---|---|---|---|
1 | 0.04766 | - | - | 0.0034 | 0.082 | 2000 (summer) |
2 | 0.02315 | 0.03016 | - | <0.001 | 0.215 | 2000 (summer) |
3 | 0.03391 | - | 0.01567 | 0.0022 | 0.110 | 2000 (summer) |
4 | 0.02094 | 0.02852 | 0.00404 | <0.001 | 0.208 | 2000 (summer) |
5 | 0.05652 | - | - | <0.001 | 0.165 | 2004 (summer) |
6 | 0.05225 | 0.00712 | - | <0.001 | 0.166 | 2004 (summer) |