Validation of Oura ring energy expenditure and steps in laboratory and free-living

A Correction to this article was published on 09 September 2023

This article has been updated

Abstract

Background

Commercial activity trackers are increasingly used in research and compared with research-based accelerometers are often less intrusive, cheaper, with improved storage and battery capacity, although typically less validated. The present study aimed to determine the validity of Oura Ring step-count and energy expenditure (EE) in both laboratory and free-living.

Methods

Oura Ring EE was compared against indirect calorimetry in the laboratory, followed by a 14-day free-living study with 32 participants wearing an Oura Ring and reference monitors (three accelerometers positioned at hip, thigh, and wrist, and pedometer) to evaluate Oura EE variables and step count.

Results

Strong correlations were shown for Oura versus indirect calorimetry in the laboratory (r = 0.93), and versus reference monitors for all variables in free-living (r ≥ 0.76). Significant (p < 0.05) mean differences for Oura versus reference methods were found for laboratory measured sitting (− 0.12 ± 0.28 MET), standing (− 0.27 ± 0.33 MET), fast walk (− 0.82 ± 1.92 MET) and very fast run (− 3.49 ± 3.94 MET), and for free-living step-count (2124 ± 4256 steps) and EE variables (MET: − 0.34-0.26; TEE: 362–494 kcal; AEE: − 487-259 kcal). In the laboratory, Oura tended to underestimate EE with increasing discrepancy as intensity increased.

Conclusion

This is the first study investigating the validity of Oura Ring EE against gold standard methods. Oura successfully identified major changes between activities and/or intensities but was less responsive to detailed deviations within activities. In free-living, Oura step-count and EE variables tightly correlated with reference monitors, though with systemic over- or underestimations indicating somewhat low intra-individual validity of the ring versus the reference monitors. However, the correlations between the devices were high, suggesting that the Oura can detect differences at group-level for active and total energy expenditure, as well as step count.

Peer Review reports

Background

Consumer-based activity trackers are increasingly used in research for measuring cardiac activity, such as heart rate (HR), heart rate variability (HRV), physical activity (PA) (e.g. steps, activity intensities, energy expenditure (EE)), and sleep (e.g. sleep stages and duration) [1,2,3,4,5]. Wearable devices reduces participation burden, thus improves adherence, compared to self-report methods such as PA logbooks [6]. The commercial devices have technologically advanced and increasingly improved comfortability and lightweight [7], and compared with research-grade accelerometers, are often less intrusive, cheaper, with improved storage and battery capacity [6, 8]. The unobtrusiveness and comfortability facilitate for convenient accumulation of large-scale, continuous, and long-term monitoring [7, 9, 10], subsequently providing novel opportunities for researchers and healthcare practitioners [7, 11]. Furthermore, long-term trends and day-to-day variations can present comprehensive insights into individuals’ health-status [7, 12]. For instance, alcohol consumption, pregnancy, fever, sleep disorders, or heavy exercise elevate mean nocturnal HR. [7] Accordingly, wearable devices may be used as a cost-effective instrument for quantification of physiological measurements in research and healthcare [7].

The Oura Ring is a new commercial multisensory wearable device that is lightweight (4–6 g) and operates for 5–7 consecutive days with one battery charge [7, 8, 11, 13]. With its subtle design, it may sometimes be preferred to more bulky activity watches or accelerometers. For physiological measurements, the ring utilises gyroscope and triaxial acceleration data, photoplethysmogram (PPG) signal, body temperature, and user’s body metrics (sex, age, body mass, height). PPG is a non-invasive optical technology that measures cyclical oscillations of blood circulation by emitting light on the skin and absorbing the light reflection through a light detector [8, 14, 15]. The ring quantifies PA (low, moderate, and high activity, inactivity, step count, MET, active EE (AEE), total EE (TEE)), body temperature, respiration rate, HR, HRV, and sleep [7, 11]. Sleep metrics [2, 7, 16], and nocturnal HR and HRV [6, 7] have been independently validated, with high accuracy and agreement in laboratory setting. Likewise, the ring has displayed promising results in monitoring the menstrual cycle based on night skin temperature [17], and been tested in predicting depression and anxiety symptoms [18], and in detecting COVID-19 [19]. Measurement of physical activity (i.e., EE) is important in healthcare research where PA is highly associated with health parameters, and accurate measurements are imperative. However, of all the PA and EE variables Oura offers, only the validity of step count, TEE, and sedentary time have been investigated [6, 20]. Those studies were only performed with ActiGraph reference monitors in free-living over 4.5 [20] or 7 days [6] with participants recruited through convenience sampling with either omitted or undefined daily PA. In addition to not validating the Oura variables with gold-standard methods, they used a narrow frequency filter (ActiGraph filter 0.29–1.63 Hz [21, 22]) for the reference methods in free-living. Although Henriksen, Svartdal [6] found strong correlations between Oura and the reference monitor for TEE and step count, measurement error and limits of agreement (LoA) were high, which was in line with Niela-Vilen, Azimi [20] findings for step count. Accordingly, the Oura Ring has potential to be used in research and healthcare. However, each variable needs to be independently validated against gold standard and reference methods in both laboratory and free-living setting in a diverse population sample for generalisation of the findings. Subsequently, that would allow for validation in both a controlled environment with well-defined workloads and highly reliable and valid equipment, as well as in a habitual setting addressing ecological validity.

The present study was designed to determine the validity of Oura Ring output. The first aim in this study sought to evaluate the accuracy of Oura Ring EE output compared with indirect calorimetry (IC) in laboratory setting. The second aim sought to evaluate the validity of Oura Ring EE variables and step count against reference monitors in free-living.

Methods

Study design

A study within the methodological project Measuring Energy expenditure and Diary intake at different Activity Levels (MEDAL) was performed to assess Oura Ring step count and EE measures and consisted of two parts: (1) a laboratory part where structured activities were performed while measuring oxygen consumption (VO2) and wearing the Oura Ring and three accelerometers positioned on the hip, thigh, and wrist; (2) a free-living part where participants wore the Oura Ring, pedometer, and accelerometers (hip, thigh, wrist) while conducting their life as normal. The laboratory part was used to validate Oura EE during different activities and intensities against IC, and for developing calibration models to predict EE for accelerometer output in free-living. Recruitment occurred between November and April 2021/22 in southwest Sweden.

Participants and recruitment

Thirty-two low and highly active participants (17 females, 15 males) were recruited through advertising on university billboards, social media, and via contacts in sport clubs. While the final sample size was similar to other Oura Ring validation studies [6, 8, 11, 16, 20, 23], the MEDAL project initially aimed to recruit 40 participants but had to accept a slightly smaller sample size due to a limited time-period for data collection and access to devices needed for measurement. The study protocol and selection criteria of participants were designed to recruit a sample with large variation in PA level to enable device validation across the whole intensity span in both controlled and normal environments. Inclusion criteria comprised of compliance to study-protocol, ability to run for 4 min at 8 km·h−1 (determined through a direct question as a part of the booking of the participant for the laboratory measurement), and aged between 20 and 40 years. Self-reported vigorous PA (equivalent to running or ball/team sports) had to be < 150 min/week (excluding walking) or > 300 min/week for inclusion in a low, respective, a high active group. Exclusion criteria consisted of: (1) individuals with PA mainly involving cycling, swimming, or strength training, (2) medical conditions affecting resting metabolic rate (RMR) or compliance to study protocol, for example untreated/poorly regulated hypo- or hyperthyroidism, diabetes, cardiac diseases, active/post COVID-19 symptoms, (3) pacemaker, artificial joints, or metal elements bilaterally in the body, (4) current/attempting pregnancy, (5) otherwise considered, by the researchers, unsuitable for the study.

Data collection

Laboratory setting

Laboratory measurements were conducted in the morning (either at 08:00 or 09:30), with participants informed to fast overnight and not to exercise the same day prior to the visit. Body mass and height were measured, and other participant characteristics (age, sex, self-reported PA frequency) collected before RMR measures (canopy with continuous airflow, lying quietly on a bed for 20 min, last 10 min used for RMR calculations) [24] followed by sensor fitting. The participant then performed five different activities according to a structured protocol while VO2 was recorded. RMR and VO2 during activity were recorded using a stationary metabolic system (Oxycon Pro, Jaeger, BD Corporation, Franklin Lakes, NJ, USA). To achieve VO2 steady state, each activity lasted for 4 min, using the last 2 min for EE calculation [25]. The activities included sitting, standing, standing-arranging books, walking (slow (4 km·h−1), fast (6 km·h−1)), and running (slow (9 km·h−1), fast (12 km·h−1), very fast (15 km·h−1), or until voluntary exhaustion). They were conducted indoors in a controlled laboratory with locomotive activities performed on a treadmill (RL2500E, Rodby, Vänge, Sweden). Metabolic equivalent of task (MET) was determined by the quotient of total activity-specific VO2 relative to the RMR VO2 [9, 21].

Free-living

Free-living data collection lasted for 2 weeks with participants wearing the Oura Ring, three accelerometers, and pedometer for the whole period, which is the longest study period, to date, for Oura Ring validation [2, 6,7,8, 11, 16, 20, 23]. The accelerometers were used in the laboratory to develop new prediction equations for EE in the free-living setting. The r2 prediction models in the laboratory were 0.932, 0.925 and 0.901 for the hip, thigh, and wrist respectively. The wearable devices were positioned identically as in the laboratory setting. All accelerometers were changed after 1 week of measurement for all participants to ensure sufficient battery and memory. All devices, but the pedometer, were waterproof. Participants were blinded to the data, except for pedometer step count. A short background questionnaire was completed at the initial visit. The participants were asked to document their sleep (bedtime, wake-up time), PA (duration, type), and device removal (time, duration) during the study period on structured self-report daily logbooks. The self-reported data were used to interpret and mitigate possible errors in the recorded data [8, 11]. Oral and written instructions and guidelines for device usage were provided.

Oura ring

The Oura Ring (Gen 2, firmware 4.0.4, Oura oy, Finland) utilise gyroscope and triaxial acceleration data, PPG signal (250 Hz), body temperature, and user’s body metrics (sex, age, body mass, and height) to determine HR, HRV, respiratory rate, sleep parameters, EE, and PA [11, 23]. The Ring provides various health-related and well-being parameters, such as estimated mean and minute-by-minute METs, AEE, TEE, PA, step count, rest duration, non-wear time, and sleep duration [8]. Oura estimates respiratory rate at 30 s resolutions, MET at 60 s resolutions, and HR, HRV, and sleep stages at 5 min resolutions [26]. Step count is provided by Oura as a daily summary of total steps. MET [27] is the main unit of EE, and is used for aerobic exercise intensity categorisation where AEE is defined and starts accumulating at > 1.5 MET [23, 28]. The data was transferred and stored after the study period, via Bluetooth, to an Oura mobile app and cloud server, where the data later was extracted from for analysis [13]. The Oura ring was fitted and worn on self-selected fingers (excluding thumb).

Accelerometers & pedometer

PA was measured by Axivity AX3 (Axivity AX3, Axivity Ltd., Newcastle upon Tyne, UK), which is a waterproof (to 1.5 m) triaxial accelerometer, equipped with temperature sensors, capturing acceleration along three orthogonal axes, can be positioned at various body locations [5], and considered feasible and practical for PA measures [5, 10]. The AX3 were set to capture acceleration at a sample rate of 100 Hz and a range of ±8 g (where 1 g is equivalent to Earth’s gravity) [21]. The accelerometer locations examined in the laboratory and free-living were wrist, hip, and thigh, which are the most commonly used positions for accelerometers in physical activity research [29]. Oura was compared to the different positions since the association could differ depending on body position. For example, the wrist position is similar to the position of the Oura ring, thus could capture and generate similar data, while the hip position is the most used accelerometer position. Wrist and hip accelerometers were attached to elastic bands placed on the non-dominant dorsal wrist and laterally above the right hip, respectively, while the thigh accelerometer was attached by medical-grade adhesive film to the mid right anterior thigh. These placements are commonly used in epidemiological and clinical research [1, 29]. The pedometer (Yamax SW200 Digi-walker, Tokyo, Japan), which is an accurate, cost-effective, and simple way of monitoring step count [30, 31], was positioned on the right hip, aligned as an extended line from right ankle and knee, inside the hip accelerometer.

Data analysis

This study investigated the accuracy of Oura MET in the laboratory against indirect calorimetry, and Oura MET, TEE, AEE, and steps count against reference monitors (3 accelerometers and pedometer) in free-living. Data analysis included the EE variables and step count extraction from the gathered data and statistical analysis leveraged to examine Oura Ring validity. Accelerometer AEE output was defined as > 1.5 MET to correspond to Oura AEE. The accelerometer output was time synchronised to the Oura ring, which reporting period starts and ends at 4 am each morning. Only valid days, defined at > 10 h of simultaneous wear-time while awake of the ring and reference monitors [4, 20], were included in the analysis. Non-wear time was defined as 60 min of zero accelerometer output after processing, with allowance of up to 2 min of interruptions below the sedentary threshold [32]. Participants were initially recruited into groups based on PA level but were combined as one group for analysis due to unbalanced groups.

Figure 1 illustrates an example of raw data gathered from the laboratory setting. Raw accelerometer data was extracted with OmGUI software (Axivity Ltd., Newcastle upon Tyne, UK) and filtered using frequency extended method (FEM, 0.29-10 Hz) [9, 21, 22], which is a wider filter and shown to outperform the original actigraph filter (0.29–1.63 Hz) [21, 22]. Linear regression was used for calibration between filtered accelerometer output and measured EE in the laboratory. The regression model was then applied to the filtered free-living accelerometer data for EE estimation. Processing of accelerometer data and synchronisation with Oura data was performed in MATLAB 2021a (MathWorks, Natick, MA, USA). The statistical analysis was done using SPSS version 28 (IBM SPSS Statistics, Armonk, NY).

Fig. 1
figure 1

Example of raw data from laboratory setting

Statistical analysis

Descriptive data are presented as mean ± standard deviation (SD) with statistical significance alpha level set to < 5%. Paired sample t-test was used for determination of bias [7, 20]. Within-individual correlations (r) were performed on pairwise EE variables and step count and then calculated as group mean (±SD) to assess the overall relationship between the Oura versus the IC (laboratory) and Oura versus the reference monitors (free-living) [7, 8, 20, 33]. Activity-by-activity correlation analysis were not performed since the structured protocol performed was designed to control both activities and intensities/velocities, thus not expecting large between-individual-variation. Correlation effect size was interpreted as: r > 0.1 small; > 0.3 moderate; > 0.5 large [33]. Mean absolute percentage error (MAPE) was calculated for the assessment of the size of the individual measurement error (%), with 10% cut-off for indication of low measurement error in free-living [6, 34]. Finally, model agreement was visualised by Bland-Altman plots [35].

Ethical considerations

The study protocol was granted by the Regional Ethical Review Board in Gothenburg (Dnr 2019–05316, Dnr 2020–00010) and performed according to the ethical principles of the Declaration of Helsinki. All participants received oral and written information regarding the study and signed informed written consent and health declaration before enrolment. Participation was voluntary, with the right to withdraw at any time and without giving any reason. Participants received one cinema ticket (100SEK) upon monitoring completion and returning of devices, for compensation of participation.

Results

Summary statistics for participant characteristics are presented in Table 1. Each participant had 5–14 (mean 13,1) valid days of free-living recording, totalling 393 valid person-days of simultaneous Oura, pedometer, and accelerometer usage. Of the 32 participants, 2 dropped out after completing the laboratory part, and 4 did not wear the ring in the laboratory but participated in the free-living part (Fig. 2). Thus, the total number of participants was 28 and 30 for the laboratory and free-living, respectively.

Table 1 Participant characteristics, mean ± SD
Fig. 2
figure 2

Study flowchart

Table 2 outlines laboratory and free-living comparisons and are visualised in Figs. 3 and 4, respectively. There was a large mean individual correlation between Oura and IC for the laboratory activities, with small underestimation (− 0.4 MET) but with a MAPE of 21.1%. The bias was close to ideal and with relatively narrow LoA. For the activity-by-activity analysis, Oura tended to underestimate EE compared with IC, with significant differences seen for sitting, standing, fast walk, and very-fast run. The measurement error was high for the stationary activities and there was increasing measurement error with increasing walking and running intensities. These differences are visualised in the Bland-Altman plot (Fig. 3).

Table 2 Mean output (±SD), mean individual correlation (±SD), mean bias (±SD), 95% limits of agreement, and measurement error (MAPE) between Oura and IC energy expenditure (MET) in laboratory setting overall and activity-by-activity, and between Oura- and accelerometer-derived EE metrics, and Oura- and pedometer-derived step metrics in the free-living setting
Fig. 3
figure 3

Comparison of Oura- and IC-derived energy expenditure metrics illustrated in a Bland-Altman plot. Squares depict the Oura and IC values for each activity performed in the laboratory by the participants. Dashed line depicts mean difference and dotted lines limits of agreement (±1.96 SD). IC, Indirect Calorimetry; MET, Metabolic Equivalent of Task

Fig. 4
figure 4

Comparison of free-living Oura- and accelerometer-derived energy expenditure metrics, and Oura- and pedometer-derived step metrics illustrated in Bland-Altman plots. Points depict the Oura and accelerometer or pedometer values for each day of data within the free-living setting. Dashed lines depict mean difference and dotted lines limits of agreement (±1.96 SD). IC, Indirect Calorimetry; Kcal, Kilo calories; MET, Metabolic Equivalent of Task

Large correlations were found for all comparisons between the Oura and reference monitors in free-living, with a close to ideal mean bias between Oura and wrist TEE (Table 2). Oura EE output was significantly different for all accelerometer comparisons, with relatively large LoA and tendencies to overestimate hip and thigh EE, and step count, while underestimating wrist EE. MAPE for free-living comparisons was only close to acceptable limits (13.0%) for wrist TEE.

Discussion

Main findings

The present study was designed to determine the validity of Oura Ring output. The first aim in this study sought to evaluate the accuracy of Oura Ring EE output compared with IC in laboratory setting. The second aim sought to evaluate the reliability of Oura Ring EE variables and step count against reference monitors in free-living. The results from the laboratory showed that the Oura successfully identified major changes between various activities and/or intensities (high individual correlation), but was less responsive to detailed deviations within different activities and/or intensities. Oura Ring step count and all EE variables correlated strongly with the reference monitors in free-living. Overall, the MET metric estimated by Oura ring corresponded best with the reference monitors.

Laboratory setting

To our knowledge, this is the first study investigating the validity of Oura Ring EE output in laboratory setting. The most noticeable was the strong individual correlation with small mean bias thus, successfully identified major changes between various activities and/or intensities. However, the ring was less responsive to detailed deviations within different activities and/or intensities, with significant underestimation for the stationary activities. Additionally, in line with previous finding in commercial activity trackers, Oura tended to underestimate EE compared with the IC with a greater discrepancy as intensity increased, with increasing individual measurement error [36,37,38]. EE during activity has been suggested to be the most unpredictable and variable component of TEE [39, 40]. Nevertheless, accuracy and validity of EE output in commercial devices have increased over the years [6, 38], however, the mean difference and measurement error for Oura Ring EE variables in the current study were greater than previously seen for Oura HR, HRV, and sleep metrics, suggesting accuracy can be improved further [3, 7, 38].

Free-living

Energy expenditure

In free-living, all Oura Ring EE variables strongly correlated with the reference monitors. Oura TEE versus wrist presented a strong correlation, agreement, and almost perfect mean bias. Surprisingly, Oura showed overall similar correspondence with the 3 accelerometers despite different placements on the body, which was unexpected, due to the ring and wrist positions resemblance. However, Fridolfsson, Arvidsson [1] have previously shown hip and thigh positions to correlate stronger with measured EE compared to the wrist. Other studies have suggested that the hip position consistently outperform the wrist which, in turn, seem to be superior to thigh [9, 37]. Nevertheless, no previous studies have investigated the accuracy of Oura AEE output, and the strong correlations indicate a reliable measure at group level of Oura AEE output compared with the accelerometers. Estimation of energy cost during activities have been shown to be the most unpredictable and variable component of TEE due to the great movement variation of PA [39, 40]. Moreover, Oura defines AEE as PA intensities exceeding 1.5 MET [28], whereas traditionally in research AEE starts accumulating 1.0 MET. The delimitation of AEE as ≥1.5 MET may be set because sedentary activity is usually recognised between 1.0–1.5 MET, while AEE often is used for measuring health behaviours. Similar to discoveries for commercial activity watches [40], Oura systematically over- or underestimated most EE variables compared with the accelerometers. Compared with the only previous study examining Oura TEE validity, the current study found a stronger correlation (r 0.79 vs r 0.70), similar measurement error (MAPE 13% vs 13%), and LoA range (85–1506 vs − 624 – 920), but larger mean bias (796 vs 148) [6] for Oura TEE compared with hip-placed accelerometers. However, the comparison with the previous study results may be limited by large variation in methodology. Since Henriksen, Svartdal [6] publication, Oura soft- and firmware have been updated, and while they used a hip-placed accelerometer, they used a different reference monitor and had less valid days which can influence MAPE. Ours is the first study examining validity of Oura MET output. Although not identical, MET and TEE output are calculated with both resting and active EE [1, 9, 27], thus generate similar information. The main proportion of TEE is usually expended during low intensity levels or at rest [39], thus, the accuracy of estimated RMR (accuracy of inputted data and equations, and the variables used for calculation) likely influence the findings for MET and TEE. Therefore, it is plausible that the measured RMR in the current study is lower than the calculated Oura RMR, which likely is based on sex, age, body mass, and height, but not disclosed by the manufacturer.

Steps

The Oura Ring step count correlated strongly with the pedometer. Meanwhile, Oura significantly overestimated step count, which have also been stated in two previous studies comparing Oura to hip- [6] or wrist-worn [20] accelerometers in free-living. The previous studies also found Oura step count to correlate strongly with the reference monitor. Moreover, Niela-Vilen, Azimi [20] reported smaller mean difference but smaller measurement error (1416, MAPE 5.2%) as the current study, while Henriksen, Svartdal [6] presented higher values (3779, MAPE 69%). The smaller mean bias identified by Niela-Vilen, Azimi [20] may be attributed to Oura and reference monitor being worn on the same hand, compared with hip-worn and/or self-selected finger as by Henriksen, Svartdal [6] and the present study. Likewise, a 2020 review on step count accuracy for consumer-based activity trackers found heterogeneity of over- and underestimation between and within brands [38]. They ascribed the observed variability to differences in wear locations and number of comparisons for each sensor.

Strength & limitations

A major strength in the study was that gold-standard criterion was used for the laboratory comparisons [39, 40]. Additionally, we investigated the Oura Ring in two conditions; (1) controlled laboratory setting, and (2) free-living (ecological validity) (3), against participant with low and high daily PA level to allow for device validation across the whole intensity span in both controlled and normal environments. Furthermore, multiple days of recordings was included for each participant [6], with simultaneous worn sensors for up to 14 days, which is the longest study period for Oura Ring validation [2, 6,7,8, 11, 16, 20, 23]. Sample size was similar to other Oura Ring validation studies [6, 8, 11, 16, 20, 23], with an even gender balance and varied level of PA, providing a diverse sample [20].

Limitations of the study includes the usage of non-gold standard criteria in free-living [39, 40], Oura Ring placement on self-selected fingers instead of on the non-dominant hand as the wrist accelerometer [20, 41], small sample size performing the fast running activities, and that only healthy participants, with a relatively small range in age and BMI, were included in our study which may limit the generalisability of the findings [11, 20].

Conclusion

In the laboratory, the Oura Ring successfully identified major changes in PA with overall small measurement error but was less responsive to detailed deviations, with increasing discrepancy along with increases in intensity. In free-living, Oura step count and all EE variables correlated strongly versus the reference monitors, but often with differences in means. The mean bias and measurement error seen for the ring in the present study were greater than for other validated Oura variables (HR, HRV, Sleep variables), suggesting potential to improve Oura EE accuracy. Accordingly, the Oura Ring cannot unambiguously be recommended to be used interchangeably with the reference monitors in the study. Lastly, while some variables presented large limits of agreement, indicating somewhat low intra-individual validity of the ring versus the reference monitors, the correlations between the devices were high, suggesting that the Oura can present differences at group-level for active and total energy expenditure, and step count. Future work should include assessing Oura EE variables against gold standard methods in free-living of different population groups.

Availability of data and materials

The present dataset is available upon reasonable request. Requests for data sharing from appropriate researchers and entities will be considered on a case-by-case basis. Interested parties should contact the corresponding author or Gothenburg University legal officer erica.schweder@gu.se.

Change history

Abbreviations

AEE:

Active Energy Expenditure

BMI:

Body Mass Index

EE:

Energy Expenditure

FEM:

Frequency Extended Method

HR:

Heart Rate

HRV:

Heart Rate Variability

IC:

Indirect Calorimetry

LoA:

Limits of Agreement

MET:

Metabolic Equivalent of Task

MAPE:

Mean Absolute Percentage Error

PA:

Physical Activity

PPG:

Photoplethysmograph/Photoplethysmogram

RMR:

Resting Metabolic Rate

SD:

Standard deviation

TEE:

Total Energy expenditure

VO2 :

Oxygen Consumption

References

  1. Fridolfsson J, Arvidsson D, Grau S. Measurement of physical activity by shoe-based accelerometers—calibration and free-living validation. Sensors. 2021;21(7):2333.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Roberts DM, Schade MM, Mathew GM, Gartenberg D, Buxton OM. Detecting sleep using heart rate and motion data from multisensor consumer-grade wearables, relative to wrist actigraphy and polysomnography. Sleep. 2020;43(7):zsaa045.

    Article  PubMed  PubMed Central  Google Scholar 

  3. Nelson BW, Allen NB. Accuracy of consumer wearable heart rate measurement during an ecologically valid 24-hour period: intraindividual validation study. JMIR mHealth uHealth. 2019;7(3):e10828.

    Article  PubMed  PubMed Central  Google Scholar 

  4. Migueles JH, Cadenas-Sanchez C, Ekelund U, Delisle Nyström C, Mora-Gonzalez J, Löf M, et al. Accelerometer data collection and processing criteria to assess physical activity and other outcomes: a systematic review and practical considerations. Sports Med. 2017;47(9):1821–45.

    Article  PubMed  PubMed Central  Google Scholar 

  5. De Craemer M, Verbestel V. Comparison of outcomes derived from the ActiGraph GT3X+ and the Axivity AX3 accelerometer to objectively measure 24-hour movement behaviors in adults: a cross-sectional study. Int J Environ Res Public Health. 2022;19(1):271.

    Article  Google Scholar 

  6. Henriksen A, Svartdal F, Grimsgaard S, Hartvigsen G, Hopstock L. Polar vantage and oura physical activity and sleep trackers: a validation and comparison study. JMIR Form Res. 2022;6(5):e27248.

  7. Kinnunen H, Rantanen A, Kenttä T, Koskimäki H. Feasible assessment of recovery and cardiovascular health: accuracy of nocturnal HR and HRV assessed via ring PPG in comparison to medical grade ECG. Physiol Meas. 2020;41(4):04NT1.

    Article  Google Scholar 

  8. Cao R, Azimi I, Sarhaddi F, Niela-Vilen H, Axelin A, Liljeberg P, et al. Accuracy assessment of Oura ring nocturnal heart rate and heart rate variability in comparison with electrocardiography in time and frequency domains: comprehensive analysis. J Med Internet Res. 2022;24(1):e27487.

    Article  PubMed  PubMed Central  Google Scholar 

  9. Arvidsson D, Fridolfsson J, Börjesson M, Andersen LB, Ekblom Ö, Dencker M, et al. Re-examination of accelerometer data processing and calibration for the assessment of physical activity intensity. Scand J Med Sci Sports. 2019;29(10):1442–52.

    Article  PubMed  Google Scholar 

  10. Hedayatrad L, Stewart T, Duncan S. Concurrent validity of actigraph gt3x+ and axivity ax3 accelerometers for estimating physical activity and sedentary behavior. J Measure Phys Behav. 2020;4(1):1–8.

    Google Scholar 

  11. Mehrabadi MA, Azimi I, Sarhaddi F, Axelin A, Niela-Vilén H, Myllyntausta S, et al. Sleep tracking of a commercially available smart ring and smartwatch against medical-grade Actigraphy in everyday settings: instrument validation study. JMIR Mhealth Uhealth. 2020;8(10):e20465.

    Article  Google Scholar 

  12. Johansen CD, Olsen RH, Pedersen LR, Kumarathurai P, Mouridsen MR, Binici Z, et al. Resting, night-time, and 24 h heart rate as markers of cardiovascular risk in middle-aged and elderly men and women with no apparent heart disease. Eur Heart J. 2013;34(23):1732–9.

    Article  PubMed  CAS  Google Scholar 

  13. Kinnunen H, Koskimäki H. 0312 the HRV of the ring-comparison of nocturnal HR and HRV between a commercially available wearable ring and ECG. Sleep. 2018;41:A120.

    Article  Google Scholar 

  14. Naeini EK, Azimi I, Rahmani AM, Liljeberg P, Dutt N. A real-time PPG quality assessment approach for healthcare internet-of-things. Proc Comput Sci. 2019;151:551–8.

    Article  Google Scholar 

  15. Nitzan M, Khanokh B, Slovik Y. The difference in pulse transit time to the toe and finger measured by photoplethysmography. Physiol Meas. 2001;23(1):85.

    Article  Google Scholar 

  16. de Zambotti M, Rosas L, Colrain IM, Baker FC. The sleep of the ring: comparison of the ŌURA sleep tracker against polysomnography. Behav Sleep Med. 2019;17(2):124–36.

    Article  PubMed  Google Scholar 

  17. Maijala A, Kinnunen H, Koskimäki H, Jämsä T, Kangas M. Nocturnal finger skin temperature in menstrual cycle tracking: ambulatory pilot study using a wearable Oura ring. BMC Womens Health. 2019;19(1):1–10.

    Article  Google Scholar 

  18. Moshe I, Terhorst Y, Opoku Asare K, Sander LB, Ferreira D, Baumeister H, et al. Predicting symptoms of depression and anxiety using smartphone and wearable data. Front Psychiatry. 2021;12:43.

  19. Poongodi M, Hamdi M, Malviya M, Sharma A, Dhiman G, Vimal S. Diagnosis and combating COVID-19 using wearable Oura smart ring with deep learning methods. Pers Ubiquit Comput. 2022;26(1):25–35.

    Article  CAS  Google Scholar 

  20. Niela-Vilen H, Azimi I, Suorsa K, Sarhaddi F, Stenholm S, Liljeberg P, et al. Comparison of Oura smart ring against ActiGraph accelerometer for measurement of physical activity and sedentary time in a free-living context. Comput Inform Nurs. 2022;40:856–62.

    PubMed  Google Scholar 

  21. Fridolfsson J, Börjesson M, Buck C, Ekblom Ö, Ekblom-Bak E, Hunsberger M, et al. Effects of frequency filtering on intensity and noise in accelerometer-based physical activity measurements. Sensors. 2019;19(9):2186.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  22. Skovdahl P, Kjellberg Olofsson C, Sunnegårdh J, Fridolfsson J, Börjesson M, Buratti S, et al. Children and adolescents treated for Valvular aortic stenosis have different physical activity patterns compared to healthy controls: a methodological study in a National Cohort. Pediatr Cardiol. 2021;42(4):774–83.

    Article  PubMed  PubMed Central  Google Scholar 

  23. Yunusova A, Lai J, Rivera AP, Hu S, Labbaf S, Rahmani AM, et al. Assessing the mental health of emerging adults through a mental health app: protocol for a prospective pilot study. JMIR Res Protoc. 2021;10(3):e25775.

    Article  PubMed  PubMed Central  Google Scholar 

  24. Compher C, Frankenfield D, Keim N, Roth-Yousey L, Group EAW. Best practice methods to apply to measurement of resting metabolic rate in adults: a systematic review. J Am Diet Assoc. 2006;106(6):881–903.

    Article  PubMed  Google Scholar 

  25. Robergs RA. A critical review of the history of low-to moderate-intensity steady-state VO2 kinetics. Sports Med. 2014;44(5):641–53.

    Article  PubMed  Google Scholar 

  26. Mason AE, Hecht FM, Davis SK, Natale JL, Hartogensis W, Damaso N, et al. Detection of COVID-19 using multimodal data from a wearable device: results from the first TemPredict study. Sci Rep. 2022;12(1):1–15.

    Google Scholar 

  27. Jetté M, Sidney K, Blümchen G. Metabolic equivalents (METS) in exercise testing, exercise prescription, and evaluation of functional capacity. Clin Cardiol. 1990;13(8):555–65.

    Article  PubMed  Google Scholar 

  28. OURA. Introducing the new Oura Ring Generation 3. [Cited 2022 February 17]. Available from: https://ouraring.com/.

  29. Arvidsson D, Fridolfsson J, Börjesson M. Measurement of physical activity in clinical practice using accelerometers. J Intern Med. 2019;286(2):137–53.

    Article  PubMed  CAS  Google Scholar 

  30. Fröberg A, Raustorp A. Integrating the pedometer into physical education: monitoring and evaluating physical activity, pedagogical implications, practical considerations, and recommendations. Phys Educ. 2019;76(1):135–55.

    Google Scholar 

  31. Strath SJ, Kaminsky LA, Ainsworth BE, Ekelund U, Freedson PS, Gary RA, et al. Guide to the assessment of physical activity: clinical and research applications: a scientific statement from the American Heart Association. Circulation. 2013;128(20):2259–79.

    Article  PubMed  Google Scholar 

  32. Troiano RP, Berrigan D, Dodd KW, Masse LC, Tilert T, McDowell M. Physical activity in the United States measured by accelerometer. Med Sci Sports Exerc. 2008;40(1):181.

    Article  PubMed  Google Scholar 

  33. Hopkins W, Marshall S, Batterham A, Hanin J. Progressive statistics for studies in sports medicine and exercise science. Med Sci Sports Exerc. 2009;41(1):3.

    Article  PubMed  Google Scholar 

  34. Nelson MB, Kaminsky LA, Dickin DC, Montoye A. Validity of consumer-based physical activity monitors for specific activity types. Med Sci Sports Exerc. 2016;48(8):1619–28.

    Article  PubMed  Google Scholar 

  35. Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571–82.

    Article  PubMed  Google Scholar 

  36. Gastin PB, Cayzer C, Dwyer D, Robertson S. Validity of the ActiGraph GT3X+ and BodyMedia SenseWear armband to estimate energy expenditure during physical activity and sport. J Sci Med Sport. 2018;21(3):291–5.

    Article  PubMed  Google Scholar 

  37. White T, Westgate K, Hollidge S, Venables M, Olivier P, Wareham N, et al. Estimating energy expenditure from wrist and thigh accelerometry in free-living adults: a doubly labelled water study. Int J Obes. 2019;43(11):2333–42.

    Article  Google Scholar 

  38. Fuller D, Colwell E, Low J, Orychock K, Tobin MA, Simango B, et al. Reliability and validity of commercially available wearable devices for measuring steps, energy expenditure, and heart rate: systematic review. JMIR mHealth uHealth. 2020;8(9):e18694.

    Article  PubMed  PubMed Central  Google Scholar 

  39. Hills AP, Mokhtar N, Byrne NM. Assessment of physical activity and energy expenditure: an overview of objective measures. Front Nutr. 2014;1:5.

    Article  PubMed  PubMed Central  Google Scholar 

  40. O’Driscoll R, Turicchi J, Beaulieu K, Scott S, Matu J, Deighton K, et al. How well do activity monitors estimate energy expenditure? A systematic review and meta-analysis of the validity of current technologies. Br J Sports Med. 2020;54(6):332–40.

    PubMed  Google Scholar 

  41. Gjoreski M, Gjoreski H, Luštrek M, Gams M. How accurately can your wrist device recognize daily activities and detect falls? Sensors. 2016;16(6):800.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Mari Wollmar, Christian Greven, Hanna Hassouneh, Ivar Holm, Jean Chelimo, Annie Guo, and Jonathan Lohaller for contributing to the data collection.

Funding

Open access funding provided by University of Gothenburg. This work was supported by grants from the Emil and Wera Cornell Foundation, the Tore Nilson Foundation, the Erik & Lily Philipsons foundation, the Swedish Heart Lung Foundation and the Swedish state under the ALF agreement between the Swedish government and the country councils (ALFGBG-965249 and ALFGBG-720851).

Author information

Authors and Affiliations

Authors

Contributions

Conceptualization, UAH, JF, DA; Methodology, UAH, JF, DA; Formal Analysis, EK, JF, DA; Data Curation, EK, UAH, JF; Writing – Original Draft Preparation, EK, UAH; Writing – Review & Editing, EK, JF, DA, AH, MB, UAH; Visualization, EK; Project Administration, UAH, AH, MB, DA; Funding Acquisition, UAH, AH, MB, DA. The author(s) read and approved the final manuscript.

Corresponding author

Correspondence to Ulrika Andersson-Hall.

Ethics declarations

Ethics approval and consent to participate

The study protocol was granted by the Regional Ethical Review Board in Gothenburg (Dnr 2019–05316, Dnr 2020–00010) and performed according to the ethical principles of the Declaration of Helsinki. All participants received oral and written information regarding the study and signed informed written consent and health declaration before enrolment.

Consent for publication

Not applicable.

Competing interests

The authors declare no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

The original online version of this article was revised: the authors requested to update the MAPE values in Table 2, and the text that is linked to the new MAPE values.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kristiansson, E., Fridolfsson, J., Arvidsson, D. et al. Validation of Oura ring energy expenditure and steps in laboratory and free-living. BMC Med Res Methodol 23, 50 (2023). https://doi.org/10.1186/s12874-023-01868-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12874-023-01868-x

Keywords